Tasks
associations are available, the SyncServer's NTP daemon may synchronize with one of
them instead of the Hardware Clock.
Using the Command Line
1. Log in to the command line interface.
2.
Enter the SETTIMEOFYEAR command followed by the time in one of the following formats:
n x.y
n mm/dd/yyyy hh:mm:ss.x
n yyyy ddd hh:mm:ss.x
n MON dd yyyy hh:mm:ss.x
n hh:mm:ss.x
In "x.y" format:
n x = UTC seconds (0-59)
n y = fractions of a second
In the remaining formats:
n mm = month 01 through 12
n dd = day 01 through 31
n ddd = day of year 001 through 366
n yyyy = four-digit year
n MON = first three letters of the month (e.g., "JAN")
n hh = hours 00 through 23
n mm = minutes 00 through 59
n ss = seconds 00 through 59
n x = fractions of a second
The SETTIMEOFYEAR command does not set the Hardware Clock to Free Run mode.
Distributing GPS Time
Note: the SyncServer model 350i does not have a GPS receiver.
SyncServers can distribute GPS time in place of UTC time.
To distribute GPS Time:
1.
On the TIMING - HW Clock page, select the checkbox next to Ignore UTC Corrections from
GPS Reference.
2.
(Recommended) On the TIMING - HW Clock page, disable all the references except GPS
by deselecting the Enable checkbox next to each one.
3.
Click the APPLY button.
4.
On the NTP - Config page, delete all the NTP associations except Hardware Clock. (Excep-
tion: Keep NTP associations that are also configured to distribute GPS time instead of
UTC.)