TIMING - Time Zone
To Restore Configuration Settings from a File
1. Click the Browse... button.
2. Navigate to the file that contains the configuration settings to be restored.
3. Click the UPLOAD button
TIMING - Time Zone
Local Time Zone
This setting affects:
n
The time shown on the SyncServer front panel display when the user presses the TIME
button. Also see TIME Button (on page 101).
n The time output by the IRIG out connector if the Output Type is set to Local on the
REFERENCES - Timecode page. Also see REFERENCES - Timecode (on page 71).
The Time Zone setting does not affect NTP or any of the other timing outputs.
To set the time zone, select a profile from the list of Time Zones and click the APPLY button.
Each profile contains the offset from UTC to the time zone, plus any rules for daylight saving
time or summer time adjustments.
The Time Zones are alphabetically organized as follows:
n Most Time Zones are sorted by continent and city name.
n Some Time Zones are sorted by country and city name.
n Some Time Zones are sorted by acronym (e.g., UTC, EST).
n Some islands are sorted by ocean (e.g., Atlantic, Pacific, Indian) or national affiliation.
Current shows the time zone in effect and the local time at the moment the page was gen-
erated.
TIMING - HW Clock
Hardware Clock Configuration
Manage the references listed under Clock Source Priorities as follows:
n
Enable or disable the reference using the checkboxes under Enable. Checking the box
enables the reference, clearing it disables the reference.
n
Change the priority of the reference by highlighting it and then using the Up/Down Arrow
buttons move it up or down in priority.
n
Restore the default priority and availability settings by clicking the DEFAULTS button.
n Each reference shows its default priority. For example, "GPS [Default 1]".
note: The SyncServer S350i does not include a GPS receiver.
Microsemi recommends using the default priorities.
The Forced Timing Source setting affects all timing outputs and displays:
997-01520-02 Rev. F1.......................................................................... Page 61