T300 Series Clothes Dryer (Condenser)
2.3 Installation as a Washer-Dryer Stack
If the appliance is to be installed as a stack, together with a washing
machine, one of the following stacking kits will be required:
Washing Machine Tumble Dryer Stacking Kit Instructions Part No.
e.g. W 760
T 368 C
or similar
WTV 310 *
WTV 311 **
1487500
e.g. W 436
T 368 C
or similar
WTV 302 1313950
Table 2-1: Stacking Kits
* without shelf between units
** with pull-out shelf between units
2.4 Draining Condensate to the Rear
T 352 C, T 358 C, T 359 C, T 367 C, T 369 C, T 369 C-2, T 377 C, T 378
C, T 382 C, T 383 C, T 388 C (T 368 C from Machine no. 7100202)
Figure 2-1: Draining Condensate to the Rear
1. Unscrew the clip from the outlet connection and remove the rubber
seal (refer to Figure 2-1 – Draining the Condensate to the Rear).
2. Fit the drain hose supplied (not with T 368 C) or other suitable hose
and affix it with the clip (refer to Section 1.12.1 Rear Drainage).