Temperature Control Units : MFC with G Series Instrument
Page: 88
Milacron Process Support Business
4165 Halfacre Road Batavia, Ohio 45103
Phone: 513-536-2584
www.milacron.com
CONDITIONS THAT TRIGGER
AN ALARM OUTPUT ON MOLD
TEMPERATURE CONTROLLERS
CONTROLLER
CONDITION T G
Incorrect 3Ø power entry Yes No
Pump overload tripped Yes Yes
High temperature fault Yes Yes
Water supply pressure fault Yes Yes
Temperature deviation Yes Yes
AVT valve malfunction Yes Yes
Sensor probe malfunction Yes Yes
BEACON AND AUDIBLE ALARMS ARE SILENCED
DURING AN ALARM CONDITION BY PRESSING
THE START BUTTON ON MICROPROCESSOR
CONTROLLER
8.7 OPTIONAL ALARM OPERATION
A. The Temptender and G Series instruments are standard with a 110 volt AC alarm output.
The alarm output can be connected to customer provided alarm annunciation, plant-wide
monitoring system or optional annunciation provided by the factory.
B. Beacon Alarms used when both visual and audible alarm annunciation is needed. The
beacon is an integral light and buzzer assembly to provide high visibility in a busy, noisy
shop. The beacon will signal until the alarm condition is acknowledged by the operator.
C. Audible alarms provide a loud signal when an alarm condition is present. The audible
alarm is mounted on the front cover of the unit.