Always check unit before applying power (see Sections 8-2 thru 8-11).
TM-246193 Page 46 Invision 352 MPa
8-19. Control Board PC1 Testing Information (Use with Section 8-20)
Ref. 276639-A / 907161
! Measure voltage of input ca-
pacitors according to Section
8-3, and be sure voltage is near
zero before touching any
parts.
Be sure plugs are secure before ap-
plying power. See Section 8-20 for
specific values during testing.
1 Control Board PC1
Test Equipment Needed:
1

Table of Contents