Chapter 4 Maintenance
4-27
1
2
2
4
5
6
8
Refill antifreeze mixed liquid.
Inject the antifreeze mixed liquid, which is
prepared in Step5, from the feed-water inlet.
Injection water slowly until the buzzer sounds.
9
When the buzzer sounds, stop refilling
and, press the key.
”To 200cc filling” will be displayed.
10
Supply 200cc of the liquid.
“Tie an infusion mouth” will be displayed.
11
Connect the tube to the feed-water inlet.
12
Press the key.
If using a 100 cc syringe, use the tube detached in
Step 6.
WaterFillUp
To200ccfilling
[ENT]
WaterFillUp
Tieaninfusionmouth
[ENT]
If press the [Enter] key without connecting the
tube to the feed-water inlet, the mixed liquid will be
overflowing.