EasyManuals Logo

Mindray DC-80 User Manual

Mindray DC-80
383 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
Image Optimization 5-27
Angle
Description
This function is used to adjust the angle between Doppler vector and flow to make
the velocity more accurate.
The real-time adjusting angle value is displayed on the right part of the spectrum
map.
Operations
Rotate the <Angle> knob on the control panel to adjust.
The adjustable angle range is -89~89°, in increments of 1°.
Quick Angle
Description
To adjust the angle faster, in increments 60°, and the real-time value of which is
displayed on the right part of the spectrum map.
Operations
Adjust through the [Quick Angle] item on the touch screen.
There are 3 angles for quickly adjustment: -60°, 0°, and 60°.
Dynamic Range
Description
The dynamic range conveys the information that being transformed from echo
intensity to gray scale.
Operations
Adjust through the [Dyn Ra.] item on the touch screen.
Effects
The more the dynamic range, the more specific the information, and the lower the
contrast with more noise.
Audio
Description
This function is used to adjust the output audio in spectrum map.
Operations
Rotate the <Volume> knob on the left of the touch panel to adjust the volume.
Press <Volume> knob to open or shut down the volume.
The adjusting range of the audio is 0-100%.
Effects
Utilizing the output audio helps to identify the feature and status of flow.
PW Steer
Description
This function provides adjustment on angles for sampling line.
Operations
Adjust through the <Steer> deflector rod on the control panel.
Effects
This feature is used to steer the direction of the beam so as to change the angle
between the beam and flow direction with immobility of the linear probe.
Values of steer angles vary by probe.
Impacts
The PW Steer function is available only for linear probes.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mindray DC-80 and is the answer not in the manual?

Mindray DC-80 Specifications

General IconGeneral
Imaging ModesB, M, Color Doppler, Power Doppler, Pulsed Wave Doppler, Continuous Wave Doppler, Tissue Doppler, 3D/4D Imaging
ProbesConvex, Linear, Phased Array, Volume
Advanced FeaturesAuto Optimization, Auto EF
ConnectivityDICOM 3.0, USB, HDMI, VGA, Ethernet
Transducer Ports4
ApplicationsAbdominal, Cardiac, Obstetrics/Gynecology, Vascular, Small Parts, Musculoskeletal, Urology, Pediatrics, Neonatal
Transducer TypesConvex, Linear, Phased Array, Volume
Power Supply100-240V AC, 50/60Hz
Operating Temperature10°C to 40°C
Storage Temperature-20°C to 60°C
Humidity30% to 80%