FrameMaker Ver.5.5E(PC) Di350 DIS/REASSEMBLY, ADJUSTMENT
98.12.09
D-40
Requirement
NOTE
This adjustment must be made when the PH Unit has been replaced and after Registration
(CD) (Printer) has been made.
Adjustment Procedure
1. Produce a test pattern. (For details, see 3-4. TEST PRINT.)
2. Check to see if width A on the test pattern meets the specifications.
If width A falls outside the specified range, perform these steps to make the adjustment.
(6) Registration (FD) (Printer)
Specification Adjust Mode Setting Range
10 ±2.0 mm Registration (FD) -19 to +19
Adjust so that width A on the test pattern output falls
within the following range.
1171D007AA
A