Minolta Di350 - Fusing Temperature Control

Minolta Di350
243 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FrameMaker Ver.5.5E(PC) Di350 GENERAL, MECHANICAL/ELECTRICAL
98.12.18
M-46
1171SBM1903A
The Fusing Roller Heater Lamp inside the Left Fusing Roller provides the following tem-
perature control.
<Temperature Control>
The Fusing Roller Thermistor detects the surface temperature of the Left Fusing Roller.
It provides an analog voltage input to the Master Board allowing the copier to control the
fusing temperature.
19-3. Fusing Temperature Control
Electrical Component Control Signal ON OFF
H1 PJ16A-8 L H
Electrical Component Control Signal Low Temp.
High Temp.
TH1 PJ16A-5 Analog input
1171M031AB
200
185
Warm-Up
Completed
(200°C)
Approx.
1 min.
Mode 1 Mode 2 Mode 3
- Temperature Control During Standby State -
Approx.
5 min.
1171M030AB
200
190
- Temperature Control During a Copy Cycle -
210
175
Special paper
Plain paper (1-sided)
Transparencies
Plain paper (2-sided)
180
Approx.
1 min.
Mode 1 Mode 2 Mode 3
Approx.
5 min.