MIOX RIO Series Operators Manual
P/N: 102-00076-G Page 54
Fault Name Condition
T
ime
Delay
(sec)
Cell
Power
Removed
W
ater
Off
Auto
Retry
No Air Flow Fault
No air flow signal while fan run
command on.
15
YES
NO
NO
Rupture Disk Fail
Liquid detected on rupture disk
probe.
2
YES
YES
NO
Contact Fail to Close
No contact status signal when
contact enable signal on.
5
NO
NO
NO
Contact Fail to Open
Contact status signal on, then
contact enable signal off.
1
YES
NO
NO
Cell Current - Very
High
Cell current greater than 125%
of target.
1
YES
NO
YES
Cell Current Variation
20% standard RIO cell current
variation calculation.
120
NO
NO
NO
Cell Voltage - Low
Cell voltage less than 30 V
when contact on.
5
NO
NO
NO
Oxidant Temp - Very
High
Oxidant temp greater than
150° F.
10
NO
NO
NO
Brine Pump Voltage
- High
Brine pump control voltage
greater than 4.85 V.
60
NO
NO
NO
Brine Pump Voltage
- Low
Brine pump control voltage
0.0 V.
60
NO
NO
NO
Low Water
Pressure
Water pressure below 35 psi
10
NO
YES
Diode Temp Fault
Diode bank temperature switch
tripped.
5
YES
NO
NO
Feed Water Temp -
Low
Feed water temperature less
than 40° F .
Feed Water Temp -
High
Inlet water temp less than 95°
F.
300
NO
NO
NO