MIOX RIO Series Operators Manual
P/N: 102-00076-G Page 59
Electrolytic Cell Replacement
Generally, the cell will have a production life of several thousand hours. However,
the life of the cell is affected by salt and water quality, water hardness, pH, and
alkalinity. It is essential that ≥ 99.5% pure salt is used, with concentrations of Ca ≤
0.03%, Mg ≤ 0.02%, and Mn ≤ 0.005%. If the following four conditions exist
simultaneously, a replacement cell may be required:
1. Oxidant temperature is high with normal water and brine flows
2.
High brine proportion pump voltage
3.
Chlorine production is significantly below normal level
4.
Salt consumption is increased.
Returning an Old/Damaged Cell
You may return a defective product to your original point of purchase, or the
authorized MIOX dealer or distributor from whom you purchased the product. Please
confirm the terms of its return policies prior to returning the product. Typically, you
must include product identification information, including installation site name,
system serial number and number of hours the cell has been used with a detailed
description of the problem you are experiencing. Pack the cell in original packing
materials or equivalent to prevent damage during shipping.
Please call your MIOX distributor for questions regarding service or cell replacement.