RDS-32 FUNCTIONALITY
23
3.6 TIME TO DOSE
The Time to Dose function shows the calculated remaining time until the dose alarm is
activated in the current dose rate field. Check the status of the Time to Dose by pressing the
Dose key twice or by navigating to TM.2.AL in the menu.
If the device shows +99h 99min there is more than 100 h left to the set dose alarm level in the
current dose rate field. See Chapter 3.5.2 Dose Alarm for details on setting the dose alarm
level.
Example of the Time to
Dose screen with more than
100 hours left until dose
alarm.
Example of the Time to
Dose screen with 8 hours 25
minutes left until dose
alarm.
The Time to Dose function can be used to help estimate the remaining work time on a
certain task or on a mission. Reset the accumulated dose and then set the dose alarm to
a suitable level, so that the user can check how much time they have left to stay in the