Converting a PRI Database on a Universal NSU
To convert a Universal NSU PRI database:
1. Install the IMAT software (page 73).
2. Launch the new IMAT and connect to the Universal NSU.
3. Load the database from your previous IMAT backup.
4. Select PRI and NSU version from Table 17 for your new database
version.
5. Convert the database and then save the new database into the NSU.
Table 17: PRI, NSU DB version to use with 3300 ICP Software version
3300 ICP Software Version Universal NSU Database Version
Release 3.0 - 3.3 (NSU or PRI card) PRI 8.0 or NSU 1.1
Release 4.0 (NSU or PRI card) PRI 8.1 or NSU 1.2
Release 4.1 - 5.0 (NSU or PRI card) PRI 8.2 or NSU 1.3
Release 5.1 (NSU) NSU 1.4
Release 5.2 (NSU) NSU 1.5
Release 5.1 - 5.2 (PRI card) PRI 8.2 or NSU 1.3
Release 6.0 and 6.1 NSU 1.5
Release 6.0 - 6.1 (PRI card) PRI 8.2 or NSU 1.3
Release 7.0 and 7.1 NSU 1.6
Release 7.0 - 7.1 (PRI card) PRI 8.2 or NSU 1.3
Release 8.0 - MCD 4.0 NSU 1.7.0.xx (See 3300 ICP RN for
specific version to use)