Initial Setup
Establish Communication with Controller
Set Controller RTC IP Address (AX, MXe, CX, CXi, CX II,
CXi II)
1. Start the communication program on the Maintenance PC.
2. Power up the controller (see page 14).
3. The communication program will instruct you to Press
<SPACE><SPACE><SPACE> to stop auto-boot AFTER
countdown starts (Release 5.2 and later) or Press any key to stop
auto-boot (prior to Release 5.2).
4. When [VxWorks Boot]: is displayed, type c and press ENTER.
5. For each VxWorks setting shown in bold inTable 49 on page 275,
enter a value, and then press ENTER. For all other settings, press
ENTER to accept the default:
- inet on ethernet (e),
IP address and subnet mask (hex) for controller
RTC (Get it from your IT administrator.)
- gateway inet (g), IP address of the default gateway for the 3300 (must
be outside the DHCP range)
- user (u), ftp
- ftp password (ftp)), ftp.
6. At [VXWorks Boot], type @, or press the Reset button on the
controller.
Tip: The Maintenance PC must be on the same subnet as the controller.
Tip: If DHCP (flags=0x40) is being used on the E2T, leave the inet on ethernet
field blank.
CAUTION: Do not use leading zeroes in the IP addresses.
For example, enter 192.168.1.2; not 192.168.001.002.
Time: The controller can take up to 10–15 minutes to restart.