87
Software Installation
9. At [VXWorks Boot], type @, or press the controller Reset button.
inet on ethernet
(e)
IP address and subnet mask (hex)
for controller RTC (for example,
134.199.63.11:ffffff00). Obtain it
from your IT administrator.
inet on backplane
(b)
host inet (h) IP address of FTP Server. Used
for software upgrades.
gateway inet (g) IP address of the end user’s
default gateway for the 3300 ICP
(must be outside the DHCP
range).
user (u) ftp User name of FTP Server.
ftp password (ftp) ftp Password of FTP Server.
flags (f) 0x0 Uses host inet IP address.
target name (n)
startup script (s)
other (o) FixPartition Used to partition a hard drive or
AX flash card that has no system
software on it.
Note: If the hard disk comes
without software, you must
use
“FixPartition” to partition the hard
disk for the install.
Note: During the installation
process, the system automatically
changes this parameter to qefcc
(CX(i) II and MXe III) or motfcc (all
other controllers).
Time: The system takes approximately 30 minutes to format the hard drive
and install the software.
Table 7: VxWorks Settings (continued)
Prompt Value Note
Page 2 of 2