2 ANALOG INPUT MODULE REPLACEMENT
2 - 5
Item A616AD
Maximum conversion speed
When using only A616AD: 1
When using a combination with A60MX: 1
When using a combination with A60MXR:
1 (Sampling processing time),
7.0 (Direct access processing)
When using a combination with A60MXRN:
1 (Sampling processing time),
7.0 (Direct access processing)
[Unit: ms/channel]
Absolute maximum input
Voltage: ±15V
Current: ±30mA
Analog input points 16 channels/module
Maximum number of writes for
E
2
PROM
-
Isolation method
Between the input terminal and programmable controller: photocoupler isolation
Between channels: non-isolated (1M resistor isolation)
Dielectric withstand voltage -
Insulation resistance -
Occupied I/O points
32 points
(I/O assignment: special 32 points)
Connected terminal 38-point terminal block
Applicable wire size
0.75 to 2mm
2
(Applicable tightening torque: 39 to 59N•cm)
Applicable solderless
terminal
V1.25-3, V1.25-YS3A, V2-S3, V2-YS3A
Internal current consumption
(5VDC)
1A
Weight 0.85kg

Table of Contents