2 ANALOG INPUT MODULE REPLACEMENT
2 - 6
: Compatible, : Partial change required, ×: Incompatible
Q68ADV Q68ADI Compatibility Precautions for replacement
80µs/channel (When there is temperature drift compensation, the time calculated by
adding 160µs will be used regardless of the number of channels used.)
The conversion speed of Q68ADV/I
to A616AD has become quick. And
then, on Q68ADV/I, the noise that did
not import on A616AD can be
imported as analog signal. In this
case, use the averaging
processing
function to remove the effect of noise.
±15V ±30mA
8 channels/module
Consider
replacement with multiple
Q68ADV/I.
Max. 100,000 times
Between the I/O terminal and programmable controller power supply:
photocoupler isolation
Between channels: non-isolated
Between the I/O terminal and programmable controller power supply:
500VAC, for 1 minute
Between the I/O terminal and programmable controller power supply:
500VDC, 20M or more
16 points
(I/O assignment: intelligent 16 points)
I/O occupied points has changed to
16 points.
18-point terminal block ×
Wiring change is required.
0.3 to 0.75mm
2
×
R1.25-3 (A solderless terminal with sleeve can not be used.) ×
0.64A 0.64A
0.19kg 0.19kg