7  POSITIONING MODULE REPLACEMENT
7 - 19
Item of AD75P-S3
Buffer memory address
AD75P-S3 QD75PN/QD75DN
Axis 1 Axis 2 Axis 3 Axis 1 Axis 2 Axis 3
Positioning start 
information
Indirect 
designation
Start No.8001 4500 4750 5000 - - -
Start No.8002 4501 4751 5001 - - -
 to  to  to  to  to  to  to
Start No.8050 4549 4799 5049 - - -
Programmable controller CPU 
memory area
Condition judgment target data 
of the condition data
5050 30000
 to   to 
5099 30049
Target axis 5100 -
Head positioning block No. 5101 -
No. of read/write data items 5102 -
Read/write request 5103 -
Read/write block 5110 to 6109 -