Appendix 5 List of Special Register Areas
SD81 to
SD111
Detailed
information 1
Detailed
information 1
SD92: Time (value set) (ms)
SD93: Time (value set) (s)
SD94: Time (actual measurement value) (ms)
SD95: Time (actual measurement value) (s)
(24) Failure information
Failure information is system information.
(27): System switching information
SD81: With or without specification
b0: System switching cause
b1: System switching instruction ID number
b2: Cause of system switching failure
b3: Control system/standby system transition
SD82: System switching cause
1: Power-off, reset, hardware failure
2: Stop error
3: System switching request from a network module
16: System switching request by using the SP.CONTSW instruction
17: System switching request using an engineering tool
SD83: System switching instruction ID number
SD84: Cause of system switching failure
1: Tracking communications disabled
2: Tracking communication timeout
3: Stop error of the standby system
4: Operating status mismatch between both systems
5: Memory copy being executed
6: Online change being executed
7: A failure of a network module detected on the standby system
8: System switching being executed
9: A redundant function module being changed online
10: System switching disabled on the standby system by using the
DCONTSW instruction
14: Safety operation mode mismatch between both systems
15: A failure of safety tracking data detected
SD85: Control system/standby system transition
1: Control system Standby system
2: Standby system Control system
(34) TEST MODE continuous RUN prevention setting
SD81: With or without specification
b0: Continuous RUN time value (second)
SD82 to SD83: Continuous RUN time value (second)
SD82: Lower word of the continuous RUN time value (second)
SD83: Upper word of the continuous RUN time value (second)
(37) Data type (tracking transfer) information
SD81: With or without specification
b0: Data type
SD82: Data type
b0: Device data
b1: Label data
b2: Signal flow
b3: PID control instruction information
b4: SFC information
b5: System switching request
b6: Operation mode change request
b15: System data
0 is stored when each data is not sent, and 1 is stored when each data is
being sent in each bit.
S (Error) ALL
No. Name Data stored Details Set by
(setting
timing)
CPU
b1b2
b0
b3
b0
b0
b15 b1b2b3b4b5b6
b0
b7b8b9