4 PARAMETERS FOR POSITIONING CONTROL
Table 4.2 Parameter Block Setting List (Continued)
No. Item
Setting range
Initial
value
Units Remarks Section mm inch degree
pulse
Setting range Units Setting range Units Setting range Units Setting range Units
8
Torque limit
value
1 to 1000[%] 300 %
• Set the torque limit value in
the servo program.
—
9
Deceleration
processing on
STOP input
0 : Deceleration stop is executed based on the deceleration time.
1 : Deceleration stop is executed based on the rapid stop deceleration time.
0 —
• Set the deceleration
processing when external
signals (STOP, FLS, RLS)
are input.
—
10
Allowable error
range for circular
interpolation
0 to 10000.0 µm 0 to 1.00000 inch 0 to 1.00000 degree 0 to 100000
pulse
100
pulse
• Set the permissible range for
the locus of the arc and the
set end point coordinates.
4.3.4
(Note-1): When the "speed control 10 multiplier setting for degree axis" is set to "valid", the setting range is 0.01 to 21474836.47[degree/min].
However, setting range of 0.001 to 2147483.647[degree/min] is displayed in the parameter block setting screen of MT Developer2.
POINTS
(1) Parameter blocks are specified in the home position return data, JOG operation
data or servo program.
(2) The various parameter block data can be changed using the servo program.
(Refer to Section 5.3.)
(3) The data set in the parameter block is used in the positioning control, home
position return and JOG operation.
(a) The parameter block No. used in the positioning control is set using MT
Developer2 at the creating of the servo program. If it is not set, control is
executed with the contents of parameter block No.1.
Also, it is possible to set parameter block data individually in the servo
program.
[Servo program editor screen]
Individual parameter
block data setting
Setting items of the
parameter block
Parameter block No.
setting
S.R. : Speed limit value
: Deceleration time
P. Torque : Torque limit value
: Allowable error range for circular
interpolation
Adv. S-curve : Advanced S-curve acceleration/
deceleration
Unit : Interpolation control unit
: Acceleration time
E : Rapid stop deceleration time
STOP : Deceleration processing on STOP input
S Ratio : S-curve ratio when S-pattern processing
is executed