EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q Series - Auxiliary Point-Specified Circular Interpolation Control

Mitsubishi Electric MELSEC-Q Series
624 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 - 41
6 POSITIONING CONTROL
6.6 Auxiliary Point-Specified Circular Interpolation Control
Circular interpolation control by specification of the end point address and auxiliary
point address (a point on the arc) for circular interpolation is executed.
Auxiliary point-specified circular uses ABS
(Absolute data method) and INC
(Incremental data method) servo instructions.
Servo
instruction
Positioning
method
Number of
control axes
Items set using MT Developer2
Speed
change
Common Arc Parameter block Others
Parameter block No.
Axis
Address/travel value
Command speed
Dwell time
M-code
Torque limit value
Auxiliary point
Radius
Central point
Interpolation control unit
Speed limit value
Acceleration time
Deceleration time
Rapid Stop deceleration time
Torque limit value
Deceleration processing on stop input
Allowable error range for circular interpolation
S-curve ratio
Advanced S-curve acceleration/deceleration
Cancel
WAIT-ON/OFF
ABS
Absolute
2
Valid
INC
Incremental
: Must be set
: Set if required
[Control details]
Control using ABS
(Absolute data method)
(1) Circular interpolation from the current stop address (address before positioning)
based on the home position through the specified auxiliary point address to the
end point address is executed.
(2) The center of the arc is the point of intersection of the perpendicular bisectors of
the start point address (current stop address) to the auxiliary point address, and
the auxiliary point address to the end point address.
Forward direction
Reverse
direction
End point address (X
1
, Y
1
)
Auxiliary point address (X
2
, Y
2
)
Arc central point
Operation by circular interpolation
0
Forward direction
Reverse direction
Start point address
(X
0
, Y
0
)
: Indicates setting data
(Note)
Fig.6.9 Circular interpolation control using absolute data method