APP - 96
APPENDICES
APPENDIX 6.2 Inverter FR-A700 series
Ver.!
FR-A700 series can be connected via SSCNET by using built-in option FR-A7AP and
FR-A7NS.
POINT
FR-A700 series cannot be used on a line where the communication type in
SSCNET setting of MT Developer2 is set to "SSCNET
/H".
QDS
(1) System configuration
The system configuration using FR-A700 series is shown below.
Servo amplifier
MR-J3(W)- B
Inverter
FR-A700 series
Inverter
FR-A700 series
Q173DSCPU/Q173DCPU(-S1) : 2 lines (Up to 32 axes)
Q172DSCPU : 1 line (Up to 16 axes)
Q172DCPU
-S1
: 1 line
U
to 8 axes
Motion CPU module
Q17 D(S)CPU
SSCNET cable
MR-J3BUS M(-A/-B)
SSCNET (CN1)
SSCNET (CN2)
Servo amplifier
MR-J3(W)- B
Ver.!
: Refer to Section 1.3 for the software version that supports this function.