6 - 35
6 POSITIONING CONTROL
(6) Motion SFC program
Motion SFC program for which executes the servo program is shown below.
SET M2042
ABS-3
Axis 1, 50000pulse
Axis 2, 40000pulse
Axis 3, 30000pulse
Speed 1000pulse/s
PX000*M2415*M2435*M2455
END
!PX000
3 axes linear interpolation control
3 axes linear
Wait until PX000 turn off after linear interpolation
completion.
Turn on all axes servo ON command.
Wait until PX000, Axis 1 servo ready, Axis 2 servo
ready and Axis 3 servo ready turn on.
3 axes linear interpolation control
Axis used . . . . . . . . . . . . Axis 1
, Axis 2, Axis 3
Command positioning speed
Vector speed . . . . . . . . 1000[pulse/s]
. . . .
Axis 1 . . . 50000[pulse]
Axis 2 . . . 40000[pulse]
Axis 3 . . . 30000[pulse]
Positioning address
interpolation control
[F10]
[G10]
[G20]
[K21]
(Note): Example of the above Motion SFC program is started using the automatic start or sequence program.