6 - 45
6 POSITIONING CONTROL
(6) Motion SFC program
Motion SFC program for which executes the servo program is shown below.
Auxiliary point-specified circular interpolation control
SET M2042
PX000*M2415*M2435
END
!PX000
Wait until PX000 turn off after circular interpolation
completion.
Turn on all axes servo ON command.
Waits until PX000, Axis 1 servo ready and Axis 2 servo
ready turn on.
Auxiliary point-specified circular interpolation control
Axis used. . . . . . . . . . . . . . . Axis 1, Axis 2
Positioning speed . . . . . . . . . . . . . . . . . . . .
. . . . . . .
Axis 1 . . . 80000[pulse]
Axis 2 . . . 30000[pulse]
End point address
Auxiliary point-specified
circular interpolation control
ABS
Axis 1, 80000pulse
Axis 2, 30000pulse
Speed 1000pulse/s
Auxiliary 1, 40000pulse
point
Auxiliary 2, 50000pulse
point
. . . . .
Axis 1 . . . 40000[pulse]
Axis 2 . . . 50000[pulse]
1000[pulse/s]
Auxiliary point address
[F10]
[G10]
[K10]
[G20]
(Note): Example of the above Motion SFC program is started using the automatic start or sequence program.