EasyManua.ls Logo

Mitsubishi Electric MELSEC-Q Series - Page 238

Mitsubishi Electric MELSEC-Q Series
624 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 - 51
6 POSITIONING CONTROL
(6) Motion SFC program
Motion SFC program for which executes the servo program is shown below.
SET M2042
PX000*M2415*M2435
END
!PX000
Wait until PX000 turn off after circular interpolation
completion.
Turn on all axes servo ON command.
Wait until PX000, Axis 1 servo ready and Axis 2 servo
ready turn on.
Radius specified-circular interpolation control
Axis used . . . . . . . . . . . . . . . Axis 1, Axis 2
Positioning speed . . . . . . . . . . . . . . . . . . . . .
. . . . . . .
Axis 1 . . . 100000[pulse]
Axis 2 . . . . 50000[pulse]
End point address
Radius specified-circular
interpolation control
ABS
Axis 1, 100000pulse
Axis 2, 50000pulse
Speed 1000pulse/s
Radius 80000pulse
1000[pulse/s]
Radius . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Radius specified-circular interpolation control
80000[pulse]
[F10]
[G10]
[G20]
[K41]
(Note): Example of the above Motion SFC program is started using the automatic start or sequence program.

Table of Contents

Other manuals for Mitsubishi Electric MELSEC-Q Series

Related product manuals