6 - 107
6 POSITIONING CONTROL
(5) Motion SFC program
Motion SFC program for which executes the servo program is shown below.
SET M2042
VPF
Axis 4, 40000pulse
Speed 1000pulse/s
Dwell 1000ms
PX000*M2475
Speed-position switching control
RST M3265
!PX000*M2461
SET M3265
M2465
Note : Shift transition is used to transit into the next processing during the positioning.
END
Speed-position
Turn on all axes servo ON command.
Wait until PX000 and Axis 4 servo ready turn on.
Speed-position switching control
Axis used . . . . . . . . . . Axis 4
Travel value . . . . . . . . 40000pulse
Command speed . . . . . 1000pulse/s
Dwell . . . . . . . . . . . . . . 1000ms
Axis 4 speed/position switching latch
Axis 4 speed/position switching enable command ON.
Axis 4 speed/position switching enable command OFF
Wait until positioning completion and PX000 turn off.
switching control
[G10]
[F10]
[K101]
[G20]
[G30]
[F20]
[F30]
(Note): Example of the above Motion SFC program is started using the automatic start or sequence program.