6 - 158
6 POSITIONING CONTROL
[Program example]
(1) FIN signal wait function by the PLC program
(a) System configuration
FIN signal wait function toward constant-speed control for Axis 1 and Axis 2.
Q172D
CPU
QX41 QY41PQ61P Q03UD
CPU
PLC CPU control module
AMP
M
Axis
1
AMP
M
Axis
2
AMP
M
Axis
4
AMP
M
Axis
3
Positioning start command : X0
(PLC CPU device)
(b) Positioning conditions
1) Constant-speed control conditions are shown below.
Item Setting
Servo program No. 0
Positioning speed 10000
FIN
acceleration/deceleration time
100[ms]
Positioning method 2 axes linear interpolation control
Pass point
Axis 1 200000 300000 350000 400000
Axis 2 200000 250000 300000 400000
M-code 10 11 12
2) Constant-speed control start command
..............................................................X0 Leading edge (OFF
ON)
(PLC CPU device)