APP - 32
APPENDICES
(4) System errors (1300 to 1399)
These errors are detected at the power-on.
The error codes, causes, processing and corrective actions are shown in Table
1.11.
Table 1.11 System error (1300 to 1399) list
Error
code
Control mode
Error cause
Error
processing
Corrective action
Positioning
Fixed-pitch feed
Speed
Speed-position switching
Speed switching
Constant-speed
JOG
Manual pulse generator
Home position return
Position follow-up control
OSC
Speed control with fixed
osition sto
Speed-torque control
1310
• Initial communication with
the Multiple CPU system did
not complete normally.
• Motion CPU fault.
Positioning
control does
not start.
• Replace the Motion CPU.
1350
• An operation cycle that the
servo amplifier does not
support has been set.
System
setting error
• Set an operation cycle that is
supported.
1360
• Number of axes set for the
master axis in servo
parameter "Driver
communication setting
(PD15)" exceed the setting
range.
• Set the number of master axis
to 4 axes or less for SSCNET
lines, and 8 axes or less for
SSCNET
/H lines in servo
parameter "PD15".
1361
• Servo parameters "Driver
communication setting
Master axis No. selection 1
for slave (PD20)" or "PD21
to PD23" are set the self
axis.
• Review the servo parameters
"PD20" or "PD21 to PD23" of
applicable slave axis.
1362
• There is no master axis
setting corresponding to the
slave axis.
1363
• Setting the driver
communication to servo
amplifier which does not
support the driver
communication.
• Confirm the driver
communication and the
actually connected servo
amplifier.
1365
• Setting the driver
communication in the
operation cycle setting of
0.2ms.
• For SSCNET
, set the
operation cycle setting to
0.4ms or more.