3 - 4
3 POSITIONING DEDICATED SIGNALS
Internal relay list (Continued)
SV13 SV22
Device
No.
Purpose
Virtual mode switching method Advanced synchronous control method
Device
No.
Purpose
Device
No.
Purpose
M8192
System area
(4096 points)
M8192
System area
(4096 points)
M8192
System area
(1608 points)
QDS
Ver.!
to to
to
M9800
Command generation axis status
(20 points
32 axes)
QDS
Ver.!
to
M10440
Synchronous encoder axis status
(10 points
12 axes)
QDS
Ver.!
to
M10560
Output axis status
(10 points
32 axes)
QDS
Ver.!
to
M10880 Synchronous control signal
[St.380]
(32 points)
QDS
Ver.!
to
M10912 Synchronous analysis complete
signal [St.381]
(32 points)
QDS
Ver.!
to
M10944
Unusable
(16 points)
QDS
Ver.!
to
M10960 Command generation axis
command signal
(20 points
32 axes)
QDS
Ver.!
to
M11600 Synchronous encoder axis
command signal
(4 points
12 axes)
QDS
Ver.!
to
M11648
Unusable
(32 points)
QDS
Ver.!
to
M11680
Output axis command signal
(10 points 32 axes)
QDS
Ver.!
to
M12000 Synchronous control start signal
[Rq.380]
(32 points)
QDS
Ver.!
to
M12032 Synchronous analysis request
signal [Rq.381]
(32 points)
QDS
Ver.!
to
M12064
Unusable
(224 points)
QDS
Ver.!
to
M12287 M12287 M12287
It can be used as a user device.
(Note-1): It can be used as a user device in the SV22 real mode only.
POINT
• Total number of user device points
• SV13 : 6352 points
• SV22 virtual mode switching method : 4704 points
(Note)
• SV22 advanced synchronous control method : 6352 points
QDS
Ver.!
(Note): Up to 6096 points can be used when not using it in the virtual mode.
Ver.!