APP - 94
APPENDICES
(e) Optional data monitor setting
The following table shows data types that can be set.
Set the total number of communication data points per 1 axis so there are
no more than 6 points on a SSCNET
/H line, and no more than 3 points on
a SSCNET
line.
Data type Unit
Number
of words
Number of
communication
data points
Data types that can be set
VC series
VPH series
QDS
Q173DSCPU/
Q172DSCPU
Q173DCPU(-S1)/
Q172DCPU(-S1)
Effective load ratio [%] 1 1
Regenerative load ratio [%] 1 1
Peak load ratio [%] 1 1
Position F/B [pulse] 2 0
Encoder position within 1
revolution
[pulse] 2 0
Encoder Multi-revolution
counter
[rev] 1 0
Position loop gain 1 [rad/s] 1 1
Bus voltage [V] 1 1
Cumulative current value
[Position
command]
(Note-1)
2 0
: Settable : Unsettable
(Note-1): The position command is the command unit set in the fixed parameter.
(f) Gain changing command, PI-PID switching command, control loop changing
command.
1) VC
series
Gain changing command and PI-PID switching command are available.
Control loop changing command becomes invalid.
2) VPH series
QDS
Gain changing command is available.
PI-PID switching command and control loop changing command
become invalid.
(g) Driver communication
QDS
The driver communication is not supported. If the driver communication is
set in a servo parameter, a major error (error code: 1363) will occur when
the power of Multiple CPU system is turned ON.