APP - 99
APPENDICES
(6) Optional data monitor setting
The following table shows data types that can be set.
Set the data so that the total number of communication points per axis is no more
than 3 points.
Data type Unit
Number of
words
Number of
communication
data points
Data types that can be set
Q173DSCPU/
Q172DSCPU
Q173DCPU(-S1)/
Q172DCPU(-S1)
Motor load ratio [%] 1 1
Position F/B [pulse] 2 0
Encoder position within 1
revolution
[pulse] 2 0
Load inertia moment ratio
[× 0.1
times]
1 1
Position loop gain [rad/s] 1 1
Converter output voltage [V] 1 1
Cumulative current value
[Position
command]
(Note-1)
2 0
: Settable : Unsettable
(Note-1): The position command is the command unit set in the fixed parameter.
POINT
When FR-A700 series is used, each data is delayed for "update delay time +
communication cycle" because of the update cycle of the inverter. The update
delay time for each data is shown in the table below.
Data type Update delay time of FR-A700 series
Motor load ratio 12.5ms
Position F/B 222µs
Encoder position within 1
revolution
222µs
Load inertia moment ratio 56ms or more (up to 2500ms)
Position loop gain 56ms or more (up to 2500ms)
Converter output voltage 9.888ms