5 - 128
Chapter 5 Data Used for Positioning Control
Storage item Storage details
[Md.122] Speed during command
This area stores the command speed during speed control mode.
"0" is stored other than during speed control mode.
Refresh cycle: Operation cycle (Speed control mode only)
[Md.123] Torque during command
This area stores the command torque during torque control mode.
(Buffer memory 0.1)%
"0" is stored other than during torque control mode.
Refresh cycle: Operation cycle (Torque control mode only)
[Md.514] HPR operating status
[CiA402 mode]
This area stores the HPR operating status.
Refresh cycle: Operation cycle