13 - 65
Chapter 13 Control Sub Functions
[3] Method of setting target position change function from PLC CPU
The following table and chart show the example of a data setting and sequence
program used to change the target position of the axis 1 by the command from
the PLC CPU, respectively. (example in which the target position value and
command speed are changed to a new target position of "300.0
m" and a new
command speed of "10000.00 mm/min".)
(1) The following data is set.
(Referring to the target position change time chart shown in item (2) below,
carry out the setting with the sequence program shown in item (3).)
Setting item
Setting
value
Setting details Buffer memory address
[Cd.27]
Target position
change value
(New address)
3000 Set the new address.
4334+100n
4335+100n
[Cd.28]
Target position
change value
(New speed)
1000000 Set the new speed.
4336+100n
4337+100n
[Cd.29]
Target position
change request
flag
1
Set "1: Requests a change in the target
position".
4338+100n
n: Axis No.-1
: Refer to Section 5.7 "List of control data" for details on the setting details.
(2) The following shows the time chart for target position change.
PLC READY signal [Y0]
READY signal [X0]
BUSY signal [X10]
V
t
Positioning start signal [Y10]
1000000
3000
Dwell time
Cd.27
Cd.28
1
0
0
Cd.29
All axis servo ON [Y1]
Target position change value
(New address)
Target position change value
(New speed)
Target position change request
flag
Start complete signal
( Md. 31 Status: b14)
Positioning complete signal
( Md. 31 Status: b15)
Error detection signal
( Md. 31 Status: b13)
Fig. 13.34 Time chart for target position change from PLC CPU