13 - 83
Chapter 13 Control Sub Functions
[2] Precautions during control
(1) Before teaching, a "machine HPR" must be carried out to establish the HP.
(When a current value changing, etc., is carried out, "[Md.20] Feed current
value" may not show absolute addresses having the HP as a reference.)
(2) Teaching cannot be carried out for positions to which movement cannot be
executed by manual control (positions to which the workpiece cannot
physically move). (During center point designation circular interpolation
control, etc., teaching of "[Da.7] Arc address" cannot be carried out if the
center point of the arc is not within the moveable range of the workpiece.)
(3) Writing to the flash ROM can be executed up to 100,000 times.
If writing to the flash ROM exceeds 100,000 times, the writing may become
impossible (assured value is up to 100,000 times).
If the error "Flash ROM write number error" (error code: 805) occurs when
writing to the flash ROM has been completed, check whether or not the
program is created so as to write continuously to the flash ROM.
[3] Data used in teaching
The following control data is used in teaching.
Setting item
Setting
value
Setting details Buffer memory address
[Cd.1]
Flash ROM write
request
1
Write the set details to the flash ROM (backup
the changed data).
5900
[Cd.38]
Teaching data
selection
Sets to which "feed current value" is written.
0: Written to "[Da.6] Positioning address/
movement amount".
1: Written to "[Da.7] Arc address".
4348+100n
[Cd.39]
Teaching
positioning data
No.
Designates the data to be taught.
(Teaching is carried out when the setting value
is 1 to 600.)
When teaching has been completed, this data
is zero cleared.
4349+100n
n: Axis No.-1
: Refer to Section 5.7 "List of control data" for details on the setting details.