Chapter 16 Troubleshooting
Classification
of errors
Error
code
Error name Error Operation status at error occurrence
Parameter
setting range
errors
910
Outside speed limit
value range
• The set value of the basic parameter 2
"Speed limit value" is outside the setting
range.
• The speed limit value is smaller than the
HPR speed.
When the PLC READY signal [Y0] is turned
from OFF to ON
: READY signal [X0] is not turned
ON.
At start : The system does not operate.
911
Outside acceleration
time 0 range
The set value of the basic parameter 2
"Acceleration time 0" is outside the setting
range.
912
Outside deceleration
time 0 range
The set value of the basic parameter 2
"Deceleration time 0" is outside the setting
range.
920
Backlash
compensation amount
error
The calculation result of the following
equation is smaller than 0 or larger than
4194304.
0 ≤
[Pr.11]×[Pr.2]
[Pr.3]×[Pr.4]
≤ 4194303
The READY signal [X0] is not turned ON.
921
Software stroke limit
upper limit
• In the unit of "degree", the set value of the
detailed parameter 1 "Software stroke
limit upper limit value" is outside the
setting range.
• In a unit other than "degree", the software
stroke limit upper limit value is smaller
than the software stroke limit lower limit
value.
922
Software stroke limit
lower limit
• In the unit of "degree", the set value of the
detailed parameter 1 "Software stroke
limit lower limit value" is outside the
setting range.
• In a unit other than "degree", the software
stroke limit upper limit value is smaller
than the software stroke limit lower limit
value.
923
Software stroke limit
selection
• The set value of the detailed parameter 1
"Software stroke limit selection" is outside
the setting range.
• In the unit of "degree", "1: Apply software
stroke limit on feed machine value" is set.
924
Software stroke limit
valid/invalid setting
The set value of the detailed parameter 1
"Software stroke limit valid/invalid setting" is
outside the setting range.