Chapter 16 Troubleshooting
Related buffer memory address
Set range
(Setting with sequence program)
Remedy
10+150n
11+150n
<Speed limit value>
1 to 1000000000 [PLS/s]
1 to 2000000000 [
10
-2
mm/min or others]
• Set a value which is not less than the HPR speed.
• With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
12+150n
13+150n
1 to 8388608
With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
14+150n
15+150n
1 to 8388608
17+150n
0 ≤
[Pr.11]×[Pr.2]
[Pr.3]×[Pr.4]
≤ 4194303
"[Pr.2] Number of pulses per rotation (AP)",
"[Pr.3] Movement amount per rotation (AL)",
"[Pr.4] Unit magnification (AM)"
"[Pr.11] Backlash compensation amount"
Review the items above.
(Refer to Section 5.2.1 or Section 5.2.3)
18+150n
19+150n
• [mm] [inch] [PLS]
–2147483648 to 2147483647
• [degree] 0 to 35999999
• Bring the setting into the setting range.
• In a unit other than degree, set so that the lower limit value is
smaller than the upper limit value.
20+150n
21+150n
• [mm] [inch] [PLS]
–2147483648 to 2147483647
• [degree] 0 to 35999999
22+150n 0, 1
• Bring the setting into the setting range.
• In the unit of "degree", set "0: Apply software stroke limit on
feed current value".
23+150n 0, 1
With the setting brought into the setting range, turn the PLC
READY signal [Y0] from OFF to ON.
n: Axis No.-1