226
(27)Parameter area initialization completed
This memory area shows whether the parameters stored in the non-volatile memory is initialized or not.
(a) Behavior of parameter area initialization
Upon the completion of setting the parameters stored in the non-volatile memory back to their default values,
Parameter area initialization completed (address: 1003H) turns to Completed (1). For the timing "Not
performed (0)Completed (1)Not performed (0)", refer to the following:
Parameter area initialization command ( Page 225, Appendix 3 (26))
(b) Default value
The default value is Not performed (0).
(c) Remote buffer memory address
The remote buffer memory address of this area is as follows:
Remote buffer memory name Main A/D converter module Extension A/D converter module
Parameter area initialization completed 1003H
The values of b1 to b15 are fixed to 0. 0: Not performed
1: Completed
b0b15 b14 b13 b12 b11 b10 b9 b8 b7 b6 b5 b4 b3 b2 b1
0000000000 0000 0