Troubleshooting and maintenance instructions Replace the fuses
SD-/SQ series 7 - 3
7.4 Replace the fuses
An error message is issued if a fuse on the interface card for the pneumatically operated gripper hand,
or on the control board, is defective. The error message contains information on which fuse has to be
replaced
7.4.1 Fuse and error messages
7.4.2 Fuse for pneumatic gripper hand
If you see error message "H0082" replace fuse S1 (rated current: 1.6 A) on board RZ375 for the
controller of the pneumatic gripper hand.
Error code Description Unit Board/Module Fuse
H0082
Fuse for pneumatic gripper hand
defective
CR2D/DU2
RZ375 F1 (rated current: 1.6 A)
CR3D/DU3
H0083
Fuse of power supply or pneumatic
gripper hand defective
CR2D/DU2
Module for installation
of the optional units
F5 (rated current: 1.6 A)
CR3D/DU3 R700SFT F2 (rated current: 1.6 A)
Tab. 7-1:
Fuses
R001495C
Fig. 7-2:
Fuse for pneumatic gripper hand