Reference Setting and
Adjustment
1.2 Setting parameter
+-Parameter
NO.
or
paramerer
error
#
#
NO
Parameter
Description
Setting range (Unit)
For gear 00,
the number of gear teeth
,$
57 39
GRAl
on the spindle side is set.
This signal is used for synchronous
tap cycle and orientation operation.
:;;)
58 3A
GP.AZ
For gear 01,
the number of gear teeth
Number of gear
on the spindle side is set.
teeth on
spin-
(Same as above)
1
-
32767
dle side
&
59
38
GRA3
Not used.
1 should be set.
I;;)
60 3C
GRA4
Not used.
1 should be set.
For gear 00, the number of gear teeth
The number of gear
on the motor shaft side is set.
teeth should be set
This signal is used for synchronous
in the manner that
tap cycle and orientation operation.
the following rela-
tionship is satisfied
Motor speed
For gear 01,
the number of gear teeth
number of gear teeth
,;;)
62 3E
GRB2
on the motor shaft side is set.
on motor shaft side
This signal is used for synchronous
Xnumber
of gear teeth
Number of gear
on spindle side
teeth on motor
tap cycle and orientation operation.
shaft side
= spindle speed
The number of gear
teeth on the spindle
$,
63 3F GRB3
Not used.
1 should be set.
and that on the motor
side should be set in
such a manner that
they have a relation
of minimum integer in
the setting range.
$
64 40
GRB4
Not used. 1 should be set.
1 to 32767
(In the case of
FR-SFJ:lOO
to 32767)
-213-