Home
Mitsubishi
Controller
GX Configurator-AD
Mitsubishi GX Configurator-AD User Manual
4
of 1
of 1 rating
208 pages
Give review
Manual
Specs
To Next Page
To Next Page
To Previous Page
To Previous Page
Loading...
7 - 8
7 - 8
MELSEC-Q
7 ONLINE MODULE CHANGE
(5)
Resumption of control
(a)
After c
hoosi
ng [Dia
gnosis
] - [O
nline
module c
hang
e] on G
X Dev
eloper
to
redi
splay
the "Online
m
odul
e change" screen,
click the [Exe
cution]
butt
o
n to
resum
e contr
ol. T
he FRO
M/TO ins
truct
ion f
or the m
odule
resum
es.
(b)
The "O
nline m
odul
e chan
ge com
plete
d" scree
n ap
pears.
152
154
Table of Contents
Default Chapter
3
Safety Precautions
3
Revisions
6
Table of Contents
7
About Manuals
11
Conformation to the EMC Directive and Low Voltage Instruction
12
About the Generic Terms and Abbreviations
13
Product Structure
14
1 Overview
15
Features
15
2 System Configuration
18
Applicable Systems
18
How to Check the Function Version, Serial Number, Product Information and Software Version
20
Cautions for Power Supply from Q61P-A1/A2 to Q64AD-GH
22
3 Specifications
24
Performance Specifications
24
Performance Specifications List
24
I/O Conversion Characteristic
27
Accuracy
32
Function List
33
A/D Conversion Methods
34
Maximum and Minimum Values Hold Function
36
Input Signal Error Detection Function
36
Warning Output Function
37
A/D Conversion Starting Time Setting Function (Q62AD-DGH Only)
41
I/O Signals for the PLC CPU
42
List of I/O Signals
42
Details of I/O Signals
44
Buffer Memory
51
Buffer Memory Assignment
51
A/D Conversion Enable/Disable Setting (Buffer Memory Address 0: Un\G0)
59
CH Average Time/Average Number of Times/Move Average/Time Constant Settings
60
(Buffer Memory Addresses 1 to 4: Un\G1 to Un\G4)
60
CH A/D Conversion Starting Time Setting (Buffer Memory Addresses 5, 6: Un\G5, Un\G6) (Q62AD-DGH Only)
60
Averaging Process Specification (Buffer Memory Address 9: Un\G9)
61
A/D Conversion Completed Flag (Buffer Memory Address 10: Un\G10)
62
CH Digital Output Value (16Bit) (Buffer Memory Addresses 11 to 14: Un\G11 to Un\G14)
62
Write Data Error Codes (Buffer Memory Address 19: Un\G19)
63
Setting Range (Buffer Memory Address 20: Un\G20)
63
Offset/Gain Setting Mode (Buffer Memory Addresses 22, 23: Un\G22, Un\G23)
64
CH Maximum Value/Minimum Value Storage Area (16Bit)
64
Input Signal Error Detection/Warning Output Settings (Buffer Memory Address 47: Un\G47)
65
Warning Output Flag (Buffer Memory Address 48 :Un\G48)
65
Input Signal Error Detection Flag (Buffer Memory Address 49: Un\G49)
66
CH Maximum Value/Minimum Value Storage Area (32Bit)
67
CH Process Alarm Upper/Lower Limit Value
67
CH Rate Alarm Warning Detection Period (Buffer Memory Addresses 118 to 121: Un\G118 to Un\G121)
68
CH Rate Alarm Upper/Lower Limit Value
69
CH Input Signal Error Detection Setting Value (Buffer Memory Addresses 138 to 141: Un\G138 to Un\G141)
70
Mode Switching Setting (Buffer Memory Addresses 158, 159: Un\G158, Un\G159)
71
Pass Data Classification Setting (Buffer Memory Addresses 200: Un\G200) (Q64AD-GH Only)
71
Industrial Shipment Settings and User Range Settings Offset/Gain Value (Buffer Memory Addresses 202 to 233: Un\G202 to Un\G233)
72
4 Setup and Procedures before Operation
73
Handling Precautions
73
Part Identification Nomenclature
75
Wiring
77
Wiring Precautions
77
External Wiring
78
Switch Setting for Intelligent Function Module
80
Offset/Gain Settings
82
Offset/Gain Settings (Q64AD-GH)
82
Offset/Gain Settings (Q62AD-DGH)
86
A/D Conversion Value Storage During Offset/Gain Setting
89
5 UTILITY PACKAGE (GX Configurator-AD)
90
Utility Package Functions
90
Installing and Uninstalling the Utility Package
91
User Precautions
91
Operating Environment
93
Explanation of Utility Package Operation
94
How to Perform Common Utility Package Operations
94
Operation Overview
97
Starting the Intelligent Function Module Utility
99
Initial Setting
102
Automatic Refresh Setting
104
Monitor/Test
106
Monitor/Test Screen
106
Offset/Gain Setting Operation
109
Confirmation of Conversion Characteristic
110
Pass Data (Q64AD-GH)
112
Pass Data (Q62AD-DGH)
114
FB Conversion of Initial Setting/Auto Refresh Setting
115
Usage of FB
116
Outline
116
Paste an FB to a Sequence Program
118
Convert (Compile) a Sequence Program
119
6 Programming
121
Programming Procedure
121
For Use in Normal System Configuration (Q64AD-GH)
122
Programming Example Using the Utility Package
123
Programming Example Without Using the Utility Package
125
For Use in Remote I/O Network (Q64AD-GH)
127
Programming Example Using the Utility Package
132
Programming Example Without Using the Utility Package
132
For Use in Normal System Configuration (Q62AD-DGH)
135
Programming Example Using the Utility Package
136
Programming Example Without Using the Utility Package
138
For Use in Remote I/O Network (Q62AD-DGH)
139
Programming Example Using the Utility Package
140
Programming Example Without Using the Utility Package
140
7 Online Module Change
146
Online Module Change Conditions
147
Online Module Change Operations
148
Online Module Change Procedure
149
When Industrial Shipment Setting Is Used and Initial Setting was Made with GX Configurator-AD
149
When Industrial Shipment Setting Is Used and Initial Setting was Made with Sequence Program
154
When User Range Setting Is Used and Initial Setting was Made with GX Configurator-AD
159
(Other System Is Available)
159
When User Range Setting Is Used and Initial Setting was Made with GX Configurator-AD
164
(Other System Is Unavailable)
164
When User Range Setting Is Used and Initial Setting was Made with Sequence Program
170
(Other System Is Available)
170
(Other System Is Unavailable)
175
Range Reference Table
176
Precautions for Online Module Change
181
8 Troubleshooting
182
Error Code List
182
Troubleshooting
183
When the "RUN" LED Is Flashing or Turned off
184
When the "ERR." LED Is on or Flashing
184
When the "ALM" LED Is on or Flashing
184
When the Digital Output Values Cannot be Read
185
When A/D Conversion Completed Flag Does Not Turn on During Use in Normal Mode
186
Checking the A/D Converter Module Status Using GX Developer System Monitor
186
Appendix
188
Appendix 1 Dedicated Instruction List and Available Devices
188
Appendix 1.1 OFFGAN
189
Appendix 2 Performance Comparison between Q64AD-GH and Q64AD
200
Appendix 3 External Dimensions
201
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Mitsubishi GX Configurator-AD and is the answer not in the manual?
Ask a question
Mitsubishi GX Configurator-AD Specifications
General
Brand
Mitsubishi
Model
GX Configurator-AD
Category
Controller
Language
English
Related product manuals
Mitsubishi QD60P8-G
128 pages
Mitsubishi Q64AD-GH
244 pages
Mitsubishi GB-50ADA-A
20 pages
MELSEC-F GRAPHIC FX DU
88 pages
Mitsubishi MELSEC
200 pages
Mitsubishi FX2N series
152 pages
Mitsubishi FX1N Series
8 pages
Mitsubishi FX3U Series
476 pages
Mitsubishi FX1S Series
466 pages
Mitsubishi QJ71C24/-R2
358 pages
Mitsubishi Alpha Series
56 pages
Mitsubishi CR800 Series
92 pages