Page #73 background image
10
LOADING AND INSTALLATION
10.2 Module Installation
10.2.1 Precaution on installation
10 - 5
9
EMC AND LOW
VOLTAGE
DIRECTIVES
10
LOADING AND
INSTALLATION
11
MAINTENANCE AND
INSPECTION
12
TROUBLESHOOTING APPENDICES INDEX
10.2 Module Installation
10.2.1 Precaution on installation
CAUTION
Use a safety PLC in the environment that meets the general specifica-
tions described in this manual.
Using this PLC in an environment outside the range of the general speci-
fications could result in electric shock, fire, erroneous operation, and
damage to or deterioration of the product
While pressing the installation lever located at the bottom of module,
insert the module fixing tab into the fixing hole in the base unit until it
stops.
Then, securely mount the module with the fixing hole as a supporting
point.Incorrect loading of the module can cause a failure or drop.
Secure the module to the base unit with screws.Tighten the screw in the
specified torque range.If the screws are too loose, it may cause a drop of
the screw or module.
Over tightening may cause a drop due to the damage of the screw or
module.
Completely turn off the externally supplied power used in the system
before mounting or removingthe module.
Not doing so could result in damage to the product.
Do not directly touch the module's conductive parts or electronic compo-
nents.
Doing so may cause malfunctions or a failure.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC and is the answer not in the manual?

Mitsubishi MELSEC Specifications

General IconGeneral
CategoryProgrammable Logic Controller (PLC)
ManufacturerMitsubishi Electric
SeriesMELSEC
Programming LanguagesLadder Diagram (LD), Function Block Diagram (FBD), Structured Text (ST), Instruction List (IL), Sequential Function Chart (SFC)
Communication ProtocolsEthernet, CC-Link, RS-232, RS-485, USB, Profibus, Modbus
Model SeriesFX, Q, L, iQ-R, iQ-F
Input Voltage100-240V AC, 24V DC (varies by model)
Memory CapacityVaries widely depending on the CPU module and series. Ranges from kilobytes to megabytes.
I/O Points16 to 8192 points (varies by model)
Communication PortsEthernet, RS-232, RS-485, USB (varies by model)
Programming SoftwareGX Works2, GX Works3, GX Developer
Operating Temperature0°C to 55°C
Storage Temperature-25°C to 75°C
Humidity5% to 95% (non-condensing)
Vibration Resistance10 to 57Hz, 0.075mm amplitude; 57 to 150Hz, 9.8m/s² acceleration
Shock Resistance147m/s², 3 times in each direction (X, Y, Z)
Protection ClassIP20 (varies by model)
CPU Processing Speed0.02μs to 0.1μs per instruction (varies by model)