4. HOW TO USE THE POINT TABLE
4 - 28
2) Absolute value command method ([Pr. PT01] = _ _ _ 1)
Setting "1" to the auxiliary function executes positioning at the speed set in the following point
table.
At this time, the position data selected at start is enabled, and the acceleration/deceleration time
constant set in the next and subsequent point tables is disabled.
By setting "1" to sub functions until point table No. 30, the operation can be performed at
maximum 31 speeds.
Always set "0" to the auxiliary function of the last point table.
To perform varying-speed operation, always set "0" to the dwell.
Setting "1" or more enables the automatic continuous positioning operation.
The following table shows an example of setting.
Point table No. Dwell [ms] (Note 1) Auxiliary function Varying-speed operation
1 0 1
Consecutive point table data
2 0 1
3 Disabled 0 (Note 2)
4 0 1
Consecutive point table data
5 0 1
6 Disabled 0 (Note 2)
Note 1.
A
lways set "0".
2.
A
lways set "0" to the auxiliary function of the last point table among the
consecutive point tables.
The following shows an operation example with the set values listed in the table below.
Point table
No.
Position data
[10
STM
μm]
Servo motor
speed [r/min]
Acceleration
time constant
[ms]
Deceleration
time constant
[ms]
Dwell [ms]
(Note 1)
Auxiliary
function
M code
(Note 3)
1 5.00 3000 100 150 0 1 05
2 3.00 2000 Disabled Disabled 0 1 10
3 2.00 1000 Disabled Disabled 0 1 15
4 6.00 500 Disabled Disabled Disabled 0 (Note 2) 20
Note 1.
A
lways set "0".
2.
A
lways set "0" to the auxiliary function of the last point table among the consecutive point tables.
3. M code will be available in the future.