5. HOW TO USE THE PROGRAM 
5 -  3 
 
5.1.3 Test operation 
Before starting an actual operation, perform a test operation to make sure that the machine operates 
normally. 
Refer to section 5.1.1 for how to power on and off the servo amplifier. 
 
Test operation of the servo motor
alone in JOG operation of test
operation mode
Test operation of the servo
motor alone
Test operation with the servo
motor and machine connected
Automatic operation with
programming
 
In this step, confirm that the servo amplifier and the servo motor operate 
normally. 
With the servo motor disconnected from the machine, use the test operation 
mode and check whether the servo motor rotates correctly at the slowest 
speed. For the test operation mode, refer to section 3.1.8 and 3.1.9 in this 
manual, and section 4.5.9 of "MR-JE-_A Servo Amplifier Instruction Manual". 
 
In this step, confirm that the servo motor rotates correctly at the slowest 
speed in the manual operation mode. 
Make sure that the servo motor rotates in the following procedure. 
 
1)  Switch on EM2 (Forced stop 2) and SON (Servo-on). When the servo 
amplifier is in a servo-on status, RD (Ready) switches on. 
 
2)  Switch on LSP (Forward rotation stroke end) and LSN (Reverse rotation 
stroke end). 
 
3)  When MD0 (Operation mode selection 1) is switched off from the 
controller and ST1 (Forward rotation start) or ST2 (Reverse rotation 
start) is switched on in the manual operation mode, the servo motor 
starts rotating. Give a low speed command at first and check the rotation 
direction, etc. of the servo motor. If the servo motor does not operate in 
the intended direction, check the input signal. 
 
In this step, connect the servo motor with the machine and confirm that the 
machine operates normally with the commands from the controller. 
Make sure that the servo motor rotates in the following procedure. 
 
1)  Switch on EM2 (Forced stop 2) and SON (Servo-on). When the servo 
amplifier is in a servo-on status, RD (Ready) switches on. 
 
2)  Switch on LSP (Forward rotation stroke end) and LSN (Reverse rotation 
stroke end). 
 
3)  When MD0 (Operation mode selection 1) is switched off from the 
controller and ST1 (Forward rotation start) or ST2 (Reverse rotation 
start) is switched on in the manual operation mode, the servo motor 
starts rotating. Give a low speed command at first and check the 
operation direction, etc. of the machine. If the servo motor does not 
operate in the intended direction, check the input signal. In the status 
display, check for any problems of the servo motor speed, load ratio, etc. 
 
Select a program from the controller, and check automatic operation.