10. COMMUNICATION FUNCTION (MITSUBISHI ELECTRIC GENERAL-PURPOSE AC SERVO PROTOCOL) 
 
10 -  19 
 
10.2.2 Input device on/off 
 
POINT 
 
The on/off status of all devices in the servo amplifier are the status of the data 
received at last. Therefore, when there is a device which must be kept on, 
transmit data which turns the device on every time. 
 
Each input device can be switched on/off. However, when the device to be switched off is in the external 
input signal, also switch off the input signal. 
 
Transmit command [9] [2] + data No. [6] [0] to [6] [2]. 
 
Command  Data No.  Setting data 
[9] [2]  [6] [0] to [6] [2]  See below. 
 
b31 b1b0
1: On
0: Off
Command of each bit is transmitted to the master station as hexadecimal data.
 
Bit 
Symbol 
Data No. [6] [0]  Data No. [6] [1]  Data No. [6] [2] 
0 SON    MD0 
1 LSP     
2 LSN     
3 TL    TCH 
4 TL1    TP0 
5 PC    TP1 
6 RES    OVR 
7 CR     
8 SP1     
9 SP2    DOG 
10 SP3     
11 ST1/RS2     
12 ST2/RS1     
13 CMX1     
14 CMX2     
15 LOP     
16   MSD  LPS 
17   PI1   
18 EM2/EM1  PI2   
19   PI3   
20 STAB2  CAMC   
21   CI0   
22   CI1   
23   CI2   
24 TSTP  CI3  DI0 
25   CLTC  DI1 
26   CPCD  DI2 
27 CDP    DI3 
28     DI4 
29      
30      
31