1. FUNCTIONS AND CONFIGURATION 
1 -  7 
 
1.4 Configuration including peripheral equipment 
 
CAUTION 
Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the servo 
amplifier may cause a malfunction. 
 
POINT 
 
Equipment other than the servo amplifier and servo motor are optional or 
recommended products. 
 
(1)  MR-JE-100A or less 
The diagram shows MR-JE-40A. 
Power factor
improving AC
reactor
(FR-HAL)
Line noise filter
(FR-BSF01)
CN3
Servo motor
Personal
computer
MR Configurator2
CN1
CN2
W
V
U
Magnetic
contactor
(MC)
L1
L2
L3
(Note 2)
Molded-case circuit
breaker (MCCB)
RS
Junction terminal block
T
Power supply
(Note 1)
 
Note   1.  For 1-phase 200 V AC to 240 V AC, connect the power supply to L1 and L3. Leave L2 open. For power supply specifications, 
refer to section 1.3 of "MR-JE-_A Servo Amplifier Instruction Manual". 
    2.  Depending on the power supply voltage and operation pattern, a bus voltage may drop, causing dynamic brake deceleration 
during forced stop deceleration. When dynamic brake deceleration is not required, delay the time to turn off the magnetic 
contactor.