6. APPLICATION OF FUNCTIONS 
6 -  41 
 
6.1.13 Cam axis position at cam control switching 
The cam axis position is determined by the positional relationship of three values of "Cam axis one cycle 
current value", "Cam axis standard position" and "Cam axis feed current value". When the control has been 
switched to the cam control (CAMC (Cam control command) is on), defining the positions of two of these 
values restores the position of the remaining one value. 
Cam axis one cycle current value
Cam axis feed current value
Cam standard position
 
The following table lists the parameters required to be set for the cam axis position restoration. Refer to 
section 6.1.7 (3) for the settings. 
 
Cam axis position 
restoration target 
([Cam control data 
No. 2]) 
Cam standard 
position setting 
method ([Cam 
control data No. 3]) 
Cam standard 
position (initial 
setting value) ([Cam 
control data No. 6]) 
Cam axis one cycle 
current value setting 
method ([Cam 
control data No. 4]) 
Cam axis one cycle 
current value (initial 
setting value) ([Cam 
control data No. 7]) 
Restoration 
processing details 
0: Cam axis one 
cycle current 
value 
   
(Note) 
 
 
(Used as the search 
starting point of cam 
pattern.) 
"Cam axis one cycle 
current value" is 
restored based on 
"Cam standard 
position" and "Cam 
axis feed current 
value". 
1: Cam standard 
position 
 
   
(Note) 
"Cam standard 
position" is restored 
based on "Cam axis 
one cycle current 
value" and "Cam axis 
feed current value". 
2: Cam axis feed 
current value 
   
(Note) 
   
(Note) 
"Cam axis feed 
current value" is 
restored based on 
"Cam axis one cycle 
current value" and 
"Cam standard 
position". 
: Required 
 