7. PARAMETERS 
7 -  15 
 
7.2 Detailed list of parameters 
 
POINT 
 
Set a value to each "x" in the "Setting digit" columns. 
 
7.2.1 Basic setting parameters ([Pr. PA_ _ ]) 
No./symbol/ 
name 
Setting 
digit 
Function 
Initial 
value 
[unit] 
Control 
mode 
CP CL 
PA01 
*STY 
Operation 
mode 
_ _ _ x  Control mode selection 
Select a control mode. 
0 to 5: Not used for positioning mode. 
6: Positioning mode (point table method) 
7: Positioning mode (program method) 
0h 
   
  _ _ x _  For manufacturer setting  0h     
  _ x _ _    0h   
  x _ _ _    1h   
PA02 
*REG 
Regenerative 
option 
 
_ _ x x  Regenerative option 
Select a regenerative option. 
Incorrect setting may cause the regenerative option to burn. 
If a selected regenerative option is not for use with the servo amplifier, [AL. 37 
Parameter error] occurs. 
 
00: Regenerative option is not used. 
For a servo amplifier of 200 W or less, no regenerative resistor is used. 
For servo amplifier of 0.4 kW to 3 kW, built-in regenerative resistor is used. 
02: MR-RB032 
03: MR-RB12 
04: MR-RB32 
05: MR-RB30 
06: MR-RB50 (Cooling fan is required.) 
00h 
   
  _ x _ _  For manufacturer setting  0h     
  x _ _ _    0h   
PA04 
*AOP1 
Function 
selection A-1 
_ _ _ x  For manufacturer setting  0h     
_ _ x _    0h   
_ x _ _    0h   
x _ _ _  Forced stop deceleration function selection 
0: Forced stop deceleration function disabled (EM1) 
2: Forced stop deceleration function enabled (EM2) 
Refer to table 7.1 for details. 
2h 
   
   
Table 7.1 Deceleration method 
  
 
Setting 
value 
EM2/EM1 
Deceleration method         
    EM2 or EM1 is off  Alarm occurred         
    0 _ _ _  EM1  MBR (Electromagnetic 
brake interlock) turns off 
without the forced stop 
deceleration. 
MBR (Electromagnetic 
brake interlock) turns off 
without the forced stop 
deceleration. 
    
    2 _ _ _  EM2  MBR (Electromagnetic 
brake interlock) turns off 
after the forced stop 
deceleration. 
MBR (Electromagnetic 
brake interlock) turns off 
after the forced stop 
deceleration.