7. PARAMETERS 
7 -  16 
 
No./symbol/ 
name 
Setting 
digit 
Function 
Initial 
value 
[unit] 
Control 
mode 
CP CL 
PA06 
*CMX 
Electronic 
gear 
numerator 
(command 
pulse 
multiplication 
numerator) 
  Set an electronic gear numerator. (Refer to section 7.3.1.) 
To enable the parameter value in the positioning mode, turn off the power for 1 s or 
more after setting and turn it on again. However, the time will be longer depending 
on a setting value of [Pr. PF25 Instantaneous power failure tough drive - Detection 
time] when "instantaneous power failure tough drive selection" is enabled in [Pr. 
PA20]. 
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear 
selection" in [Pr. PA21]. 
Set the electronic gear within the following range. Setting out of the range will trigger 
[AL. 37 Parameter error]. 
1/27649 < CMX/CDV < 8484 
 
Setting range: 1 to 16777215 
1 
   
PA07 
*CDV 
Electronic 
gear 
denominator 
(command 
pulse 
multiplication 
denominator) 
  Set an electronic gear denominator. (Refer to section 7.3.1.) 
To enable the parameter value in the positioning mode, turn off the power for 1 s or 
more after setting and turn it on again. However, the time will be longer depending 
on a setting value of [Pr. PF25 Instantaneous power failure tough drive - Detection 
time] when "instantaneous power failure tough drive selection" is enabled in [Pr. 
PA20]. 
To enable the parameter, select "Electronic gear (0 _ _ _)" of "Electronic gear 
selection" in [Pr. PA21]. 
Set the electronic gear within the range of [Pr. PA06]. 
Setting out of the range will trigger [AL. 37 Parameter error]. 
 
Setting range: 1 to 16777215 
1