3. DISPLAY AND OPERATION SECTIONS 
3 -  23 
 
3.1.10 Teaching function 
After an operation travels to a target position (MEND (Travel completion) is turned on) with a JOG operation 
or manual pulse generator operation, pushing the "SET" button of the operation area or turning on TCH 
(Teach) will import the position data. This function is available only in the point table method. In other control 
modes, the display remains the same. 
 
(1) Teaching preparation 
 
 
Teaching setting initial display 
Press the "SET" button for approximately 2 s to switch to the teaching setting 
mode. 
 
 
When the lower three digits blink, press the "UP" or "DOWN" button to select 
the point table. 
 
 
When the lower three digits blink, press the "SET" button to complete the 
teaching setting preparation. The upper two digits on the display will blink on 
completion of proper preparation 
 
(2)  Position data setting method 
After an operation travels to a target position (MEND (Travel completion) is turned on) with a JOG 
operation or manual pulse generator operation, pushing the "SET" button of the operation part or turning 
on TCH (Teach) will set the positioning address as position data. 
 
 
When the upper two digits blink, the current position is written to the selected 
point table by pressing the "SET" button. 
 
When the upper two digits or the lower two digits blink, the display returns to the teaching setting initial 
screen by pressing the "MODE" button. 
The following shows the conditions for when the teaching function operates. 
 
(a)  When the "positioning command method" of [Pr. PT01] is set to absolute value command method (_ 
_ _ 0) 
 
(b)  Home position return completion (ZP (Home position return completion) is turned on) 
 
(c)  While the servo motor is stopped (command output = 0, MEND (Travel completion) is turned on)