1. FUNCTIONS AND CONFIGURATION 
1 -  8 
 
(2)  MR-JE-200A or more 
The diagram shows MR-JE-200A. 
Power factor
improving AC
reactor
(FR-HAL)
Line noise filter
(FR-BSF01)
CN3
Personal
computer
MR Configurator2
CN1
CN2
W
V
U
Magnetic
contactor
(MC)
L1
L2
L3
(Note 2)
Molded-case
circuit breaker
(MCCB)
RS T
Junction terminal block
Power
supply
(Note 1)
Servo motor
 
Note   1. 
 1-phase 200 V AC to 240 V AC power supply may be used with the servo amplifier of MR-JE-200A. For 1-phase 200 V AC 
to 240 V AC, connect the power supply to L1 and L2. Leave L3 open. For power supply specifications, refer to section 1.3 of 
"MR-JE-_A Servo Amplifier Instruction Manual". 
    2  Depending on the power supply voltage and operation pattern, a bus voltage may drop, causing dynamic brake deceleration 
during forced stop deceleration. When dynamic brake deceleration is not required, delay the time to turn off the magnetic 
contactor.